MAINTENANCE

Cartridge Change

To replace:.

Shut off water supply to both inlets

Remove the control lever (1), remove the grub screws (2-4), pay attention not to lose the small O-ring
(3).

Take off the control handle (5) and pull out the cup (6).

Unscrew the flange (7) using 30mm/1

1

/

6”

spanner. Remove the cartridge (8).

Before re-assembling cartridge (8) clean its housing with wet cloth.

Re-assembling the flange (7).

Re-fit the cup (6).

Re-fit the control knob (5) and fix it with the grub screws (2-4).

Place the small O-ring (3) and re-fit the lever (1).