Cartridge change – Blu Bathworks TSP101 User Manual

Page 4

Advertising
background image

2013-07

1 866 907 0122 blubathworks.com

®

3

MAINTENANCE

Cartridge Change

To replace:.
•

Shut off water supply to both inlets

•

Remove the control lever (1), remove the grub screw (2), take off the control handle (3) and pull out the
cup (4).

•

Pay attention not to lose the O-ring (5).

•

Unscrew the flange (6) using 30mm/1

1

/

16

”

spanner. Remove the cartridge (7).

•

Before re-assembling cartridge (7) clean its housing with wet cloth.

•

Re-assembling the flange (6) and the O-ring (5).

•

Re-fit the cup (4).

•

Re-fit the control knob (3) and fix it with the grub screw (2).

•

Re-fit the lever (1).

 

 

 