MAINTENANCE

Cartridge Change

To replace:.

Shut off water supply to both inlets

Remove the control lever (1), remove the grub screw (2), take off the control handle (3) and pull out the
cup (4).

Pay attention not to lose the O-ring (5).

Unscrew the flange (6) using 30mm/1

1

/

16

spanner. Remove the cartridge (7).

Before re-assembling cartridge (7) clean its housing with wet cloth.

Re-assembling the flange (6) and the O-ring (5).

Re-fit the cup (4).

Re-fit the control knob (3) and fix it with the grub screw (2).