Cartridge change – Blu Bathworks TSU101 User Manual

Page 4

Advertising
background image

2013-07

1 866 907 0122 blubathworks.com

®

3

MAINTENANCE

Cartridge Change

To replace:.

Shut off water supply to both inlets

Remove the control lever (1), remove the O-ring (2) and the grub screws(3), take off the control handle
(4) and pull out the cup (5).

Pay attention not to lose the O-ring (6).

Unscrew the flange (7) using 30mm / 1

1

/

16

spanner. Remove the cartridge (8).

Before re-assembling cartridge (8) clean its housing with wet cloth.

Re-assembling the flange (7) and the O-ring (6).

Re-fit the cup (5).

Re-fit the control knob (3) and fix it with the grub screws (3).

Place the O-ring (2) and re-fit the lever (1).

 

 

 