Cartridge change – Blu Bathworks TSU101 User Manual
Page 4
Advertising
2013-07
1 866 907 0122 blubathworks.com
®
3
MAINTENANCE
Cartridge Change
To replace:.
•
Shut off water supply to both inlets
•
Remove the control lever (1), remove the O-ring (2) and the grub screws(3), take off the control handle
(4) and pull out the cup (5).
•
Pay attention not to lose the O-ring (6).
•
Unscrew the flange (7) using 30mm / 1
1
/
16
spanner. Remove the cartridge (8).
•
Before re-assembling cartridge (8) clean its housing with wet cloth.
•
Re-assembling the flange (7) and the O-ring (6).
•
Re-fit the cup (5).
•
Re-fit the control knob (3) and fix it with the grub screws (3).
•
Place the O-ring (2) and re-fit the lever (1).