CARTRIDGE CHANGE
To replace it follow the instruction hereunder.
•

Shut off water supply to both inlets

•

Remove the cap (1), remove the grub screw (2), take off the control handle (3) and remove
the screw (4).

•

Remove the centering insert (5) and unscrew the cap (6).

•

Pay attention not to lose the O-ring (7) and pull out the plate (8).

•

Unscrew the flange (9) using 28mm/1

1

/

9

' spanner. Remove the cartridge (10).

•

Before re-assembling cartridge (10) clean its housing with wet cloth.

•

Re-assembling the flange (9) and the plate (8), place the O-ring (7) and screw the cap (6).

•

Re-fit the centering insert (5) and fix it with the screw (4).

•

Place the control knob (3) and fix it with the grub screw (2)

•

Re-fit the small cap (1).

IMPORTANT
In case of reduction of flow rate, dismantle the aerator and clean the filter inside or change it.