Blu Bathworks TSP211 User Manual

Page 3

Advertising
background image

2013-07

1 866 907 0122 blubathworks.com

®

2

CARTRIDGE CHANGE
Through years of use impurities and limescale could damage the cartridge. To replace it, refer-
ence the following instruction.

Shut off water supply to both inlets

Remove the control lever (1), remove the screw (2), take off the control handle (3) and pull
out the cup (4).

Pay attention not to lose the O-ring (5).

Unscrew the flange (6) using 30mm/1

1

/

6

” spanner. Remove the cartridge (7).

Before re-assembling cartridge (7) clean its housing with wet cloth.

Re-assembling the flange (6).

Place the O-ring (5) and re-fit the cap (4).

Re-fit the control knob (3) and fix it with the grub screw (2).

Re-fit the lever (1).

IMPORTANT
In case of reduction of flow rate, dismantle the aerator and clean the filter inside or change it.