CARTRIDGE CHANGE
Through years of use impurities and limescale could damage the cartridge. To replace it, refer-
ence the following instruction.
•

Shut off water supply to both inlets

•

Remove the cap (1), remove the grub screw (2), take off the control handle (3).

•

Remove the screw(4) and the centering insert (5).

•

Unscrew the flange (6) using 30mm / 1

1

/

6

” spanner. Remove the cartridge (7).

•

Before re-assembling cartridge (7) clean its housing with wet cloth.

•

Re-assembling the flange (6) the centering insert (5) and fix it with the screw (4).

•

Re-fit the control knob (3) and fix it with the grub screw (2).

•

Re-fit the cap (1).

IMPORTANT
In case of reduction of flow rate, dismantle the aerator and clean the filter inside or change it.