CARTRIDGE CHANGE
Through years of use impurities and limescale could damage the cartridge. To replace it, refer-
ence the following instruction.
•
Shut off water supply to both inlets
•
Remove the cap (1), remove the grub screw (2), take off the control handle (3).
•
Remove the screw(4) and the centering insert (5).
•
Unscrew the flange (6) using 30mm / 1
1
/
6
” spanner. Remove the cartridge (7).
•
Before re-assembling cartridge (7) clean its housing with wet cloth.
•
Re-assembling the flange (6) the centering insert (5) and fix it with the screw (4).
•
Re-fit the control knob (3) and fix it with the grub screw (2).
•
Re-fit the cap (1).
IMPORTANT