Troubleshooting guide, Burner goes off on safety 27 – Boyertown Regal Oil Fired Furnace Variable Speed 2 Stage ECM Motor User Manual

Page 27

Advertising
background image

Troubleshooting Guide


This equipment must be serviced, adjusted and started only by a qualified service

agency – an individual or agency, licensed and experienced with all codes and ordinances, and is
responsible for the installation and adjustment of the equipment.

WARNING

Oil T ank Full

Bleed Oil Lines

Oil flows Freely

Air in Oil Lines

Fill T ank

Fuel Supply

Valves Open

Open All

Supply Valve

s

Oil Filter Clean

Replace Oil

Filter

Pump Strainer

Clean

Clean or

Replace Strainer

Adjust Pressure

Per Set-up Label

Refer to Burner

Manual

Pump Pressure

Per Set-up Labe

l

Spark Established

Ignition Electrode

Shorted or

Cracked Porcelain

Replace

Electrodes

Refer to Burner

Manual

Replace

Nozzle

Nozzle Clean and

Matches

Preliminary Settings

Air Settings Match

Preliminary

Settings

Adjust Air

Settings

Refer to Burner

Manual for Control

T rouble Shooting

Check All Fitting

Connections

No

No

No

No

No

No

No

No

Yes

Yes

Yes

Yes

Yes

No

Yes

No

No

Yes

Yes

Yes

Yes

No

Burner Goes Off on Safety

27