Earthing Requirements

4.0

Earthing Requirements

WARNING! THIS APPLIANCE MUST BE EARTHED.

IMPORTANT: The wires in the mains lead are colour coded in accordance

with the following code.

Green and Yellow......Earth

Blue......Neutral

Brown......Live

As the colours of the wires in the mains lead may not correspond with
the markings identifying the terminals in your plug, proceed as
follows.

! The wire which is coloured Green and Yellow or Green must be connected

to the terminal which is marked with the letter ‘E’ or by the Earth signal
or which is coloured Green and Yellow or Green.

" The wire which is coloured Blue must be connected to the terminal

labelled ‘N’ or coloured Black or Blue.

# The wire which is coloured Brown must be connected to the terminal

labelled ‘L’ or coloured Red or Brown.

Those units supplied to the North American market will have an integral
moulded 3 pin connector which is provided to satisfy required local standards.

The mains voltage selector switch provides a simple external adjustment to
allow operation on all international AC power standards. The allowable ranges
for the supply voltage are:

90VAC up to 132VAC on the 115V position and

190VAC up to 264VAC on the 230V position.

Outside these ranges the unit will not work satisfactorily, if at all. Voltages in
excess of the maximum will probably cause damage. Voltages below the
minimum will cause the power supplies to drop out of regulation, degrading
the performance of the system.