Preventive maintenance / cw-11 circle welder – BUG-O Systems CW-11 User Manual

Page 45

Advertising
background image

45

Refer to CW-11 Electrical Component Chart. (Pg. 27)

CW-11 Collector Item #3:

The collector ring should be sanded once a year. If the collector ring is pitted too badly it should be replaced. Inspect

all wires coming out of the collector ring for cut or missing insulation. All wires should be fastened to the center shaft

with a nylon cable tie. Tighten four set screws if needed.

Weld Cable Inlet 3/0 Item #10:

Ensure that the cable is fastened tightly to the collector ring. Inspect the cable for cut or missing insulation. Make sure

the micarta insulation tube on the cable is in good condition. Replace the cable if necessary.

Solenoid Adaptor Kit Item #15:

Inspect for damage. Replace if necessary.

LN-9 Control Cables #11, 12, 13:

Inspect the cable for cuts or missing insulation. Ensure that the elbow connector is not damaged. Ensure that all

terminal ends are snug. Replace cable if necessary.

PREVENTIVE MAINTENANCE / CW-11 CIRCLE WELDER

Advertising