Features and Functions of the AHC Control Unit:

A. Main Power Switch - Turn control power on or off.
B. Auxiliary Power Receptacle
C. Circuit Breaker Reset - Resets control circuit after overload.
D. Power Cord - Input power to the Control Unit
E. Pilot Light - Lit when Control Unit is plugged in and turned on.
F. Current Set Point Control and Display - Displays AHC current setpoint (in amps); range 0 -

500 amps. Turn knob clockwise to increase set point, counterclockwise to decrease.

G. Motor Connection (Cap & Chain) - Plug cable from motorized racker here.
H. Speed Control - Regulates the speed of vertical travel. Turn knob clockwise to increase

speed, counterclockwise to decrease.

J. Shunt & Filter Receptacle - Connect cable from Shunt and Filter Assembly here.
K. Manual Jog Switch - Used to raise and lower vertical racker when not welding. Overrides

AHC when welding.

All vertical racking for the FTS-1025 is motorized and controlled with the AHC Control Unit (shown
below).

A

G

H

J

K

F

E

D

C

B