PCB-1213 adJUSTMENT POT

The

amp dial setting MdS aHC Remote Control (CaS-2051-10) may not exactly match the amp dial

on the power source. If precise matching is important, one can calibrate the system so that they match

using the

adjustment Pot (PCB-1213) found inside the Hall Effect Current Sensor Assembly (CAS-

1550).

While the system is welding and the Auto Height Control is “ACTIVE”, turn the

adjusting Screw using

a small “Jeweler’s Style” screw driver.

As this screw is turned, the

amp dial on the power source will change. When the display on the

welding power source matches the

amp dial setting, the system is calibrated.

NOTE: This adjustment is not normally needed.