PCB-1213 adJUSTMENT POT
The
amp dial setting MdS aHC Remote Control (CaS-2051-10) may not exactly match the amp dial
on the power source. If precise matching is important, one can calibrate the system so that they match
using the
adjustment Pot (PCB-1213) found inside the Hall Effect Current Sensor Assembly (CAS-
1550).
While the system is welding and the Auto Height Control is “ACTIVE”, turn the
adjusting Screw using
a small “Jeweler’s Style” screw driver.
As this screw is turned, the
amp dial on the power source will change. When the display on the
welding power source matches the
amp dial setting, the system is calibrated.
NOTE: This adjustment is not normally needed.