background image

3-18

X16 MADI Merge Unit

Revision MM2006-1

Select Wordclock Master or Slave. Press the Wordclock switch
to select either Master or Slave. LED indication is provided to
confirm selection. See

3.5.4 Wordclock Synchronisation

for fur-

ther details on how this operates.

Select whether Wordclock termination is required if receiving an
external clock source. If it is, then press in the 75 Ohm termina-
tion switch (located on the rear panel) and the corresponding
front panel LED will illuminate.

NOTE: Wordclock termination is only required if the X16 is syn-
chronising to external wordclock and it is either a) the only de-
vice connected to the master clock source, or b) at the end of a
daisy-chain of connected devices (not best practice!)

If all settings correspond with the connected MADI devices and eve-
rything is synchronised properly, the corresponding green MADI In
LEDs located on the far left of the front panel (see

3.1 X16 Front

Panel

) will illuminate. If problems do occur then these LEDs will pro-

vide status indication to enable quick trouble shooting. For further in-
formation concerning see

3.5.5 X16 LED Error Indication

.