8.

Remove heater base from fireplace. If installing optional con-
trol accessories, do so at this time. Follow all directions pro-
vided with accessory.

9.

Drill holes at marked locations using 3/16" drill bit.

10. Attach base assembly to fireplace floor using two masonry

screws (in hardware package).

Fitting

Flexible Gas Hose (if
allowed by local codes)

CONNECTING TO GAS SUPPLY

WARNING: A qualified service person must con-

nect heater to gas supply. Follow all local codes.

WARNING: Never connect propane/LP heater di-

rectly to the propane/LP supply. This heater requires an
external regulator (not supplied). Install the external
regulator between the heater and propane/LP supply.

WARNING: Never connect natural gas heater to

private (non-utility) gas wells. This gas is commonly
known as wellhead gas.

O
F

F

P

IL

OT

O

N

H

I

L

O

Figure 11 - Attaching Flexible Gas Hose to Heater

Figure 12 - Attaching Base Assembly to Fireplace Floor

Masonry Screw

Mounting
Flanges

INSTALLATION

Continued

INSTALLING HEATER BASE ASSEMBLY

WARNING: If installing in a sunken fireplace,

special care is needed. You must raise the fireplace
floor to allow access to heater control panel. This will
insure adequate air flow and guard against sooting.
Raise fireplace floor with noncombustible material.
Make sure material is secure.

CAUTION: Do not pick up heater base assembly

by the burner. This could damage heater. Only handle
base assembly by grates.

WARNING: You must secure this heater to fire-

place floor. If not, heater will move when you adjust
controls. Moving heater may cause a gas leak.

IMPORTANT:

Make sure the heater burner is level. If heater is not

level, heater will not work properly.

Installation Items Needed

• hardware package (provided with heater)

• approved flexible gas hose (not provided) (if allowed by local

codes)

• sealant (resistant to propane/LP gas, not provided)

• electric drill with 3/16" drill bit (metal or masonry as applicable)

• flathead screwdriver

1.

Apply pipe joint sealant lightly to male threads of the fitting to
be threaded into gas control. Connect approved flexible gas hose
to gas control fitting in heater (see Figure 11).

IMPORTANT:

Hold gas fitting with wrench when connecting flexible gas hose.

2.

Locate two masonry screws in hardware package.

3.

Place heater base in fireplace.

4.

Place logs in their proper position on heater base. See Install-
ing Logs,
page 13.

5.

Center heater base and logs front-to-back and side-to-side in
fireplace.

6.

Carefully remove logs without moving heater base.

7.

Mark screw locations through one hole on each side of the
mounting bracket (see Figure 12). If installing in a brick-bot-
tom fireplace, mark screw locations in mortar joint of bricks.

CAUTION: Do not remove the data plates attached

to the heater base assembly. The data plates contain
important warranty and safety information.

INSTALLATION

Installing Heater Base Assembly
Connecting To Gas Supply