GROUNDING

INSTRUCTIONS

This stove is for use on 120 volts. The cord has a

plug as shown in Figure 2. An adapter is available

for connecting three-blade grounding-type plugs

to two-slot receptacles. The green grounding lug

extending from the adapter must be connected to

a permanent ground such as a properly grounded

outlet box. The adapter should not be used if a

three-slot grounded receptacle is available.

Figure 2 - Grounding Methods

Figure 3 - Electric Stove Control Panel

OPERATING

INSTRUCTIONS

Once the unit has been properly connected to a

ground electrical outlet, it is ready to operate.
Note:

Ensure the circuit breakers for power

supply are turned on.

CONTROL PANEL OPERATION

Controls are located on the back of the unit near

the top (see Figure 3).

1. Main ON/OFF power switch: This switch is

located at the furthest right corner on the

control panel when looking at the back of

the unit. Turn the switch to ON and unit

will be ready to operate. The "|" indicates

ON and "O" indicates OFF.

2. Flame ON/OFF Switch: This switch is

located in the middle between the Main

ON/OFF switch and the Heater ON/OFF

switch on the control panel when looking at

the back of the unit. Turn the switch to ON

and the flame effect will turn on. The "|"

indicates ON and the "O" indicates OFF.

3. Heater ON/OFF Switch: This switch is

located to the left of the Flame ON/OFF

switch on the control panel. It has a symbol

of the sun directly below it.

4. Thermostat Control Dial: This dial is located

at the furthest left corner on the control panel.

It has a symbol of a thermostat directly below

it. Turn the dial clockwise past the number 8.

Built-In

Thermostat

Main Power

Switch

Flame Switch

Heater Switch

Grounding Pin

Adapter

You should hear a small clicking sound indicat-

ing the heater has started and heat will emit

from the vents at the top of the unit from the

front. To turn off heater, turn the dial counter

clockwise past number 1 and turn the Heater

Switch to OFF position. To increase the desired

temperature, turn the dial clockwise towards

Number 9.

CLEANING AND

MAINTENANCE

WARNING: Always discon-

nect power and allow the heater

to cool before performing any

cleaning, maintenance or reloca-

tion of this heater. Turn controls

to OFF and remove plug from

outlet or turn off circuit breaker

to heater.

Turn off heater and circuit breaker to heater before

performing any cleaning and/or maintenance. Al-

low heater to cool completely.

BULB REPLACEMENT

WARNING: The halogen light

bulbs in your unit can become

extremely hot. Allow at least 10

minutes between turning off the

heater and removing the light

bulbs to avoid accidental burns.

There are a total of 4 ( halogen light bulbs (type

GX6.35 rated 120 volts, 35 watts) in your unit.
• 1 bulbs provide illumination for the ember bed

beneath the log set

• 1 bulbs provide illumination for the flame

generation assembly

• 2 bulbs for replacement