For proper working, it is recommended to in-
stall the appliance at a distance of 2000
- 2100 mm from the floor.
Before starting the appliance installation,
please check that all components are not da-
maged,
in such a case contact your retailer and do not
carry out installation.

Furthermore, please read carefully all of the
following installation instructions.
- Use an exhausting pipe whose maximum
length does not exceed 5 meters.
- Limit the no. of elbows in the piping, since
each elbow reduces the air capacity
of 1 linear meter. (Ex.: if you use no. 2 x 90 °
elbows, the length of piping must not exceed
3 meters).
- Avoid abrupt direction changes.
- Use a 150 mm constant diameter pipe for
the whole length.
- Use piping approved by standards in force.

INSTALLATION

CE1500 - CE1100 - CE1105

Fit a false ceiling with an opening of the fol-
lowing sizes:

CE1500: 1465x965 mm with a minimum di-
stance of 270 mm between the ceiling and
the false ceiling;

CE1100: 1065x665 mm with a minimum di-
stance of 270 mm between the ceiling and
the false ceiling.

CE1105: 1050x645 mm with a minimum di-
stance of 250 mm between the ceiling and
the false ceiling;

It is possible to select the side of the hood
where the air suctioned can be discharged.
After having chosen the most suitable posi-
tion, prepare the ducting: an air outlet con-
nection piece, with a diameter of 150 mm to
be installed in the side selected, is provided
with the appliance.
Leave any unused exhaust outlets closed.
Draw the outline of the hole to house the cei-
ling-mounted hood on the solid ceiling (Fig.
1), according to the model chosen; make 4
holes in the ceiling according to the dimen-
sions shown in (Fig. 2); place the metric plugs
provided in the holes.
Open the stainless steel panels, following
the instructions mentioned in the USES sec-
tion, and remove the grease filters in order
to avoid damaging them in any way and too
allow installation (Fig. 3); screw the threa-
ded bars provided into the plugs (Fig.4); the
threaded bars are 250 mm long and serve to
install the ceiling-mounted hood at a distan-
ce from the solid ceiling of between 270 mm
and 370 mm (Fig. 5); If the hood is installed
with lateral air outlet, fit a false ceiling with
an opening that has a minimum gap of 210
mm between the ceiling and the false ceiling
(Fig. 12); in case of a larger gap between the
hood and the ceiling, you need to use longer
threaded bars.