Ready Remote 24927 User Manual

Page 72

Advertising
background image

69

© 2 0 0 6 D i r e c t e d E l e c t r o n i c s

To active Panic Mode:

Press and hold the

button on the transmitter for 6

seconds

The Horn/Siren output and light flash will activate for
45 seconds

To de-active Panic Mode:

Press and release the

button on the transmitter

Arm or Disarm the alarm system

Zone Bypass Feature

The Zone Bypass feature temporarily bypasses alarm inputs that
trigger excessively when the system is armed while monitoring the
other inputs for triggers. This keeps constant triggers due to envi-
ronmental reasons from annoying the neighbors.

Protected entry bypass:

If the door, hood, brake or ignition inputs become activated
through 3 consecutive 30 second full trigger durations, it will be
bypassed until it has become inactive for more than 5 seconds.

Sensor bypass:

If one of the sensor inputs is triggered 3 times within 1 hour, a
bypass timer will begin and that input will be bypassed for 1 hour.
If a trigger occurs on that input while the bypass timer is active,
the bypass timer will reset.

You can Disarm and then Rearm the alarm to defeat the sensor
bypass at any time.

Advertising