ULTRA FLAME DIRECT VENT GAS STOVE

9

Installation of Wall Venting Kits

Direct Vent Kit

VENT TERMINAL

RADIATION SHIELD

-min 1"

-max 60"

Direct Vent

Direct Vent Details

1. Move the stove to its position;

2. Install temporary a 8 in. section (4) to visualize where the opening to be done thru the wall. Center of the

opening should be at about 23 ½ “above the base of the stove;

Note: Horizontal run should have a slope of ¼ in per foot.

3. Make a 10-1/2" x 10-1/2" opening in the wall, 23-1/2"

inches in order to introduce the radiation shield thru
the wall;

4. Cut the radiation shield to length if necessary and

install as shown. Secure with four #10 1” wood screws;

5. Install the vent terminal (13) with 2 ½ screws (12). You

may want to remove the vent casing for easy access
and manipulation, Keep only in place the wall plate

6. Insert the 8 in. pipe into the round opening of the

interior black wall plate (7). Fix the insulation pad (9)
around the 8 in. pipe with the aluminum tape;

7. Keeping the insulation joint of the 8 in. pipe down,

insert it into the vent terminal wall plate;

8. Secure the 8 in. pipe to vent terminal wall plate with

the metal screw;

9. Fix finally the vent terminal wall plate with six 2 ½ in

screws (12).

10. Insert the 5 in. flexible pipe (3) into the 8 in. pipe and

fix it to the vent terminal casing. Use high temperature
silicone and one locking band to secure it in pace;

NOTE: All joints must be sealed with RTV silicone, 315

°C.

(600

°F) temperature resistance.

11. Install the vent casing and the cover in place

12. Seal around the terminal to prevent water leakage into

the house

CUT TO LENGTH

10-1/2" X 10-1/2"
OPENING