12 CB 9 Series Installation Instructions

1.0

FOUNDATION – (see Anchor Bolt Installation Instructions)

2.0

SET THE UNIT

2.1

Screw one set of nuts and washers onto the anchor bolts – After the foundation has

set, screw one set of nuts followed by one set of washers onto the anchor bolts. Set the

nuts such that the lowest washer is about 2½ inches above the concrete and at an even

height. To accomplish this, use a small level and check all three directions. These nuts

are not adjustable after the unit is in place. The bottom edge of the Code Blue unit will be

½-inch above the concrete when installed.

IMPORTANT: The leveling of the bottom nuts is crucial to the leveling of the unit. A small

error in the adjustment of these will be magnified after installation.

IMPORTANT: A ½-inch air gap is required between the foundation and the unit. Moisture

problems may result if this condition is not complied with.

2.2

Set the unit on the anchor bolts – Align the phone plate in the desired direction and lift

the Code Blue unit over the anchor bolts. Note that the unit weighs 190-420 pounds. Use

appropriate lifting materials and methods to avoid possible injury and/or damage.

2.3

Secure the unit – Access the mounting studs through the door on the side of the unit.

Place the second washer and nut and then tighten the mounting nuts onto the anchor

bolts. This may be more convenient if a long socket, extension and universal joint is used

to tighten the hardware.

3.0 WIRING

3.1

Ground – The ground (green) wire should be stripped and fastened to the supplied ground-

ing lug.

3.2

24V AC supply – Using the proper crimping tool, attach a #8 fork to each of the incoming

power wires and fasten them to the terminal screws labeled “Line” and “Neutral.”

3.3

120/240V AC supply – Using the proper crimping tool, attach a #8 fork to each of the in-

coming power wires and fasten them to the correct terminals as labeled on the transformer.
After completing the wire connections, install the supplied terminal covers.

See diagrams next page

All wiring must be installed and connected by experienced and certified personnel to meet

local and national electrical codes, and will include a service disconnect.