INSTALLATION

Continued

For Built-In Installation

WARNING: A licensed elec-

trician must connect the wiring

harness to electrical supply

following all local codes. Electri-

cian must provide a clamp on the

box cover to secure the wiring.

Wiring should be routed through

the bushing in the hole on the

outer casing of fireplace.

1. Install snap bushing from blower kit into

one hole on rear of remote/blower bracket

(see Figure 18). The other hole is for a strain

relief clamp (not supplied) to secure incoming

electrical supply.

2. Follow steps 2 through 6 in Installing Blower

Accessory, page 14.

3. A licensed electrician must follow the wiring

diagram to connect incoming electrical supply

to fan kit wiring harness (see Figure 19).

4. Plug power cord to outlet receptacle (not

provided) as shown in Figure 18. Wind extra

cable of power cord and tie up with plastic

wire strap (see Figure 18). Set cable bundle

between the remote/blower bracket and outer

casing, away from the burner.

5. Test to make sure blower is working properly.
6. Reinstall upper louver beginning with bottom

screws (see Figure 12, page 12) and close

lower louver.

3
2
1

O

F
F


P

ILO

T

O

N

H

I




L

O

Blower Bracket
Assembly

Screw

Wire Harness

Switch
Plate

Switch

Power Cord

Outlet Receptacle
(not included)

Remote/ Blower
Bracket

Clamp Connector
(not included)

Figure 18 - Installing Blower Bracket Assembly

Plastic Wire Strap Wire Harness

Lower Louver Door

Red

Red

Fan Switch

(Auto/Off/On)

Blue

Blue

Thermostat

Switch

(N.O.)

Green

White

Green

White

On

110/115

V.A.C.

Blower

Motor

Black

Off

1

2

3

Auto

Extension Cord
Use extension cord if needed. The cord must have

a three-prong, grounding plug and a three-hole

receptacle. Make sure cord is in good shape. It must

be heavy enough to carry the current needed. An un-

dersized cord will cause a drop in line voltage. This

will result in loss of power and overheating. Use a

No. 16 AWG cord for lengths less than 50 feet.

Figure 19 - Wiring Diagram For Blower

Accessory Built-In Installation