120 VAC Trumpet Horn Installation (Incandescent)
11
Section 5:
120 VAC Trumpet Horn Installation
(Incandescent)
Refer to Drawing C-220009 in Appendix A for general wiring details of incandescent scoreboard horns.
The following section describes the 120 VAC trumpet horn installation for an incandescent
scoreboard. Assemblies are only available for 120 VAC scoreboards.
Note: Disconnect power to the scoreboard before installing the horn!
5.1 Equipment
The trumpet horn kit consists of:
a horn
a metal mounting angle
assorted #10 screws, tapping screws, and nuts
5.2 Location
The horn entrance panel is typically located in the center of the lower half of the scoreboard
(refer to the component location drawings included in the scoreboard manual for specific
location). The horn will be mounted directly to this entrance panel. The panel may be secured
only by screws, or it may have hinges that allow it to swing open.
5.3 Basic Horn Installation
If the horn kit was ordered with the scoreboard, the horn interface card, mounting angle,
and horn body were likely installed at the factory; follow the simple instructions below.
If these components have not been installed, skip ahead to Section 5.4.
1. Locate the horn entrance panel (see Section 5.2).
2. Locate and screw the trumpet part of the horn into the horn body through the 2"
knockout on this panel.
5.4 Complete Horn Installation
Reference Drawings:
Horn Installation ....................................................................................... Drawing A-44197
Template, Hole Drilling, Trumpet Horn .................................................... Drawing A-83502
Assy; Trumpet Horn Kit ............................................................................ Drawing A-88563
1. Locate the horn entrance panel (see Section 5.2). There should be a 2" knockout on
this panel. Remove this knockout. If the knockout has not been provided, use
Drawing A-83502 as a guide to drill one 2" hole in the panel.
Note 1: Be careful not to damage any internal components when drilling!
Note 2: The knockout may have been removed at the factory.