Rack Mount Player Pre-Installation Verification

DD2620510 Rev 02

19 March 2014

PO Box 5128 201 Daktronics Drive, Brookings, SD 57006-5128

tel: 800-325-8766 fax: 605-697-4700

www.daktronics.com

5. Verify the IP settings match the site IP settings.

• View the properties for each LAN connection.

• Compare settings with the intended site's IP settings.

6. If everything is functioning properly, you are ready to go

to site. If the player is not functioning properly:

a. Remove the power cord from the player.

b. Remove the player lid.

c. Verify all cards and riser cards are properly seated.

Refer to Figure 4 and Figure 5.

d. Verify all cable connections are seated properly. Refer

to Figure 6.

e. Reinstall the lid and reconnect power.

f. Repeat Steps 1 - 5 to check player function. If the

player functions properly, you are ready to go to

site. If the player is not operating properly, order a

replacement player.

Figure 4: Properly and Improperly Seated
Riser Card Connection

Figure 5: Properly and Improperly Seated Riser Card

Figure 6: Properly and Improperly Seated Power
Cable