Rack mount player pre-installation verification – Daktronics Rack Mount Player User Manual
Page 2

Rack Mount Player Pre-Installation Verification
DD2620510 Rev 02
19 March 2014
PO Box 5128 201 Daktronics Drive, Brookings, SD 57006-5128
tel: 800-325-8766 fax: 605-697-4700
www.daktronics.com
5. Verify the IP settings match the site IP settings.
• View the properties for each LAN connection.
• Compare settings with the intended site's IP settings.
6. If everything is functioning properly, you are ready to go
to site. If the player is not functioning properly:
a. Remove the power cord from the player.
b. Remove the player lid.
c. Verify all cards and riser cards are properly seated.
Refer to Figure 4 and Figure 5.
d. Verify all cable connections are seated properly. Refer
to Figure 6.
e. Reinstall the lid and reconnect power.
f. Repeat Steps 1 - 5 to check player function. If the
player functions properly, you are ready to go to
site. If the player is not operating properly, order a
replacement player.
Figure 4: Properly and Improperly Seated
Riser Card Connection
Figure 5: Properly and Improperly Seated Riser Card
Figure 6: Properly and Improperly Seated Power
Cable