Redundant CPE Applications

The T-APS can be used for switching a T1/EI circuit between two sets of CPE for redundant equipment
operation. The Working Mode selection can be either 1+1, Blind 1 or Blind 2.

In the 1+1 and Blind 1 modes, TX signals from the CO will be present at each of the two CPE devices.

In Blind 2 mode only the current selected working path will see the TX signals. The alternate path will not
provide TX to it’s associated CPE while the Protective Path is working.

3: SET LINE FORMAT

T1 Setting Selections: [ UNFRAMD SF ESF ]
E1 Setting Selections: [ UNFRAMD CAS CCS CAS&C CCS&C ]

4: SET LINE CODE

T1 Setting: Selections -

[ B8ZS AMI ]

E1 Setting: Selections -

[ HDB3 AMI ]

5: RX SENSITIVITY (NETWORK)

Selections – [ LONG

SHORT ]


LONG: T1 Setting Sensitivity is –36 dB.
E1 Setting Sensitivity is –43 dB.

SHORT: T1 Setting Sensitivity is –15 dB.

E1 Setting Sensitivity is –10 dB

6: SET BUILDOUT (NETWORK)

T1Setting Selections: [ DSX1-1 DSX1-2 DSX1-3 DSX1-4 DSX1-5 -7.5dB -15dB -22dB ]

DSX1-1 0 to 133 feet
DSX1-2 133 to 266 feet
DSX1-3 266 to 399 feet
DSX1-4 399 to 533 feet
DSX1-5 533 to 655 feet
-7.5dB CSU
-15dB CSU
-22dB CSU


E1 Setting Selections

: [ 120Nor 120Hi ]

120 Nor:

120Ω Normal Return Loss.

120 Hi:

120Ω High Return Loss.

7: RX SENSITIVITY (USER)

Selections - [ LONG SHORT ]


LONG: T1 Setting Sensitivity is –36 dB.

E1 Setting Sensitivity is –43 dB.

SHORT: T1 Setting Sensitivity is –15 dB.

E1 Setting Sensitivity is –12 dB.