always respond to a request in the public community. The settable SNMP community is
configured with the

[ COMM=”Double Quoted String” | NONE ]

option. The community may be

in any case. The double quote encapsulation is not part of the community string. The settable
community may be cleared by setting it to the keyword

NONE

.

The MIB-II variables sysName, sysContact, and sysLocation may be initialized from the UTM
non-volatile database using the SNMP command. These variables are volatile in that they may be
over-written by an SNMP manager. However, any change made by the SNMP manager will not
impact the UTM non-volatile database. Setting the value to NONE will clear the entries in the
UTM non-volatile database. Each field may be of 31 characters or less. The double quote
encapsulation is not part of the respective variable. Any of the variables may be cleared by
setting it to the keyword

NONE

.

5.2.19 INSTALL ( S

OFTWARE

R

EGISTRATION

)

Syntax: install [ key=<software key> ]

[ fpkey=<software key>]

The UTM has a unique device software key, and multiple per interface feature package keys.
This section is included in the user manual for completeness. Under normal circumstances, only
the mechanized utilities utilize this command. It may be executed manually under an emergency
situation. Depending on the device, the keys may or may not be installed by the factory. The per
port feature package keys my be added at any time, and do not affect the operation of the unit.
The registration procedure does not require a restart to take effect on a device running the
registered software.

When executed without arguments, the install command will display the significant information
needed to manufacture the device software key. The device IP address may also be required. No
additional information is needed to create the feature package keys.

The

key=<software key>

argument allows the entry of an eight-character alphanumeric software

registration that is unique to this UTM device. If an invalid key is entered, a MINOR alarm is
generated to that effect. The passwords are not altered. The

rstpass

command has been created

to reset the passwords should that become necessary.

The

fpkey=<software key>

argument allows the entry of an eight-character alphanumeric

software registration that is unique to an interface, and software feature package, on this UTM
device for the current software build. The specific feature package referenced by the software key
becomes immediately available on the port without subsequent download. The <software key>
has effect on only one interface. Other interfaces on the device are not affected. If the same
software feature package is needed on multiple interfaces, then multiple feature package keys
are applied.

The install command is always available.