Connection, With electromechanical meter, With electronic meter – Delta Dore TYWATT TRI User Manual

Page 3

Advertising
background image

- 5 -

With electromechanical meter

Ph 1

Ph 1

Ph 2

Ph 3

N

Ph 1

HC

N

Ph1

Ph2

Ph3

Ph 2

T.I.

Ph 3

6 7

1

2

3

4

5

8 9

10 11 12 13

TYWATT TRI

Off peak hours input must be phase 1 and can be "reused"
on the day/night switch of the DHW control (hot water tank)
or on the off-peak hours decoupling relay.

Towards branch circuit-breaker and

three-phase electromechanical meter

HC

230-400 V – 50 Hz power supply

Electronic

meter

Electric water

heater

Day/night

switch

Connection

With electronic meter

Ph 1

Ph 2

Ph 3

N

Branch

circuit-breaker

Three-phase

electronic

meter

Ph 1

HC

N

Ph1 Ph2 Ph3

Ph 2

T.I.

Ph 3

Electronic

meter

6 7

1

2

3

4

5

8 9

10 11 12 13

TYWATT TRI

The continuity
wire must
be earthed

1 pair telephone

cable (6/10e)

with continuity wire

230-400 V – 50 Hz power supply

The principle of the diagrams produced must be retained.

- Standard UTE C15-100 and good practice must be

complied with.

- Connected or nearby equipment must not generate

excessive interference (directive 2004/108/EEC).