Digi-Star GT465 User Manual
Page 34
 
34
GT465 Operators Manual
D3968 Rev A
Setting/
Display
D.A.N Options
(
Bold
= Default)
Description
MENU 5. CONTROL SETTINGS
Diagnostic Enable 
(
DIAG
DIAG
DIAG
DIAG
)
508
ON
, OFF
Enables diagnostic information. – 
Press SELECT do display DIAG, 
then press FUNCTION to display 
RPM 
RPM Start/Stop 
Control 
(rssctl
rssctl
rssctl
rssctl)
531
ON,OFF
ON, enables AUTOLOG feature
RPM/Stop Speed
(rssmin
rssmin
rssmin
rssmin)
532
300
Set to 20 – 50% of PTO operating 
RPMs. Stop is activated with this 
value. 
Rpm Start Tol 
Speed 
(rsstol
rsstol
rsstol
rsstol)
533
100
Set to 10% of PTO operating 
RPM’s. Start is activated using the 
value + DAN 532. 
RPM Start Delay
(rsstoy
rsstoy
rsstoy
rsstoy)
534
3.0
Start activated when RPMs above 
DAN 532 + DAN 533 for this time in 
seconds. 
RPM Stop Delay
(rsspoy
rsspoy
rsspoy
rsspoy)
535
2.0
Stop activated when RPMs below 
DAN 532 for this time in seconds. 
CALIBRATION
Setup Number
(
SETUP
SETUP
SETUP
SETUP
)
871
Quick entry method selects weigh 
method 1-4lbs, 5-8kg, gain 1-9, 
display counts 1-9 and capacity 
*1000. 
Calibration Number
(
CAL
CAL
CAL
CAL
)
872
Weight displayed at .4mV/V for 
these load cells.