Matching ez scale to another scale – Digi-Star EZ 3200/EZ 3200V/EZ 3200V RC User Manual

Page 8

Advertising
background image

Digi-Star Model EZ3200/EZ3200V/EZ3200V RC

4. Matching EZ scale to another scale

5

! copyright - 10/24/2001

4. Matching EZ scale to another scale

Sometimes two different scales are used to weigh the same load. When this is done, the weight
measured by each scale may not be the same. This can be caused by one or both of the two scales
being slightly out of calibration. This indicator has the ability to match any other scale, even if
that scale is not calibrated.

To match your EZ scale (Scale A) to another scale (Scale B) you must determine the Calibration
Multiplier. To do this, place a load on Scale A (feed wagon, etc...) and write down the weight
displayed. Repeat several times to determine the average weight. Next, place the same load on
Scale B and again write down the weight displayed.

Repeat several times to determine the average weight. Use the following formula to determine
the Calibration Multiplier for the EZ’s "CAL" number:

!

It is important to use an average of several weights before calibrating the scale.

SCALE MATCHING EXAMPLE

Original

SETUP #

127060

CAL#

23980

1 trial

2 trial

3 trial

Scale B

30,000

30,580

28,000

Scale A

29,440

29,800

27,500

1.020 +

1.026 +

1.018 = 3.064

B ÷ A

3.064 ÷ 3 trials = 1.021 Cal. Multiplier

New EZCAL# = Orig. EZCAL# × Cal.Multiplier

24484 = 23980 × 1.021

!

You should not modify your "SETUP" number. Only your "CAL" number.

Follow the instructions:

TO CHANGE SETUP/CALIBRATION NUMBERS

shown on the next

page.

SCALE INFORMATION SHEET

Original

SETUP #

..................

CAL#

..................

SCALE MATCHING WORK SHEET

1 trial

2 trial

3 trial

Scale B
Scale A

B ÷ A

÷ 3 trials = Cal. Multiplier

New EZCAL# = Orig. EZCAL# × Cal.Multiplier

........................ = ....................... × ..........................

Advertising