Digi-Star SW3300 User Manual
Page 12
 
11
Extension tube may be cut down to provide a custom scale width. Simply re-drill the 
mounting cross-hole after cutting down the pipe on one end. 
 
Wires and cables must be stowed and secured safely to prevent damage. Secure all 
cables of off ground and away from animals with nylon cable ties or other fasteners. 
 
 
 
 
 
 
Maintenance: 
There are no moving parts and no lubrication required. The only maintenance required 
is periodic cleaning of the mounts and the area below the scale to assure free and 
unencumbered operation of the scale. If a pressure washer is being used, do not spray 
or direct high pressure stream at the load cells. Load cell damage may occur. 
 
Stand over each of the 4 corners to troubleshoot for problems. Corners should weigh 
the same within ±2 display counts. Scale system accuracy is ±1% maximum error. 
Do not weld to load cells with load cell cables connected to the indicator. If you must 
weld with load cells connected, locate welder ground so that current will not flow 
through the load cell. 
Important
Assembly Diagram 14k Load Cells 
 
NOTE PROPER 
ORIENTATION