Digi-Star SW3300 User Manual

Page 19

Advertising
background image

Installation & Operation

D3746 19

Assemble load cells to deck as shown on page 25. Make sure

both load cell cables come out the same side as the indicator

support and the cable plate (located under one of the side

channels).

Assemble indicator support, 1” ram mount and handle/wheels

option as shown on page 25. The ram mount should be mounted

on the channel support side which has the cable plate.

Load cell cable routing: Loosen cable retainer plate and push the

plate outward. Begin by taking the two cable load cell connectors

and feed them through the 1.5” diameter hole from the bottom

toward the indicator support, Figure 3. Weave the load cell cable

through the support arm toward the indicator, Figure 4. Attach the

load cell connector to the indicator and pull any excess cable

back down toward the deck.

At each load cell, push the cable through the retaining plate slot,

Figure 1 and Figure 2. All extra cable is tucked inside the deck

channel. When complete, push the cable retaining plate toward

the deck to close off the channel. Tighten the three ¼” bolts to

hold the retaining plate in position.

MAINTENANCE

There are no moving parts and no lubrication required. The only

maintenance required is periodic cleaning of the mounts and the

area below the scale to assure free and unencumbered operation

of the scale. If a pressure washer is being used, do not spray or

direct high pressure stream at the load cells. Load cell damage

may occur.

Stand over each of the 4 corners to troubleshoot for problems.

Corners should weigh the same within ± 1% maximum error.

Advertising