Delta Electronics GFB0412SHE User Manual

Dimensions drawing, P & q curve, Mounting panel cutout

Advertising
background image

40 x 50 x 38 MM SERIES

GFB

DIMENSIONS DRAWING

mm

(INCH)

UNIT:

P & Q CURVE

(AT RATED VOLTAGE)

MOUNTING PANEL CUTOUT

mm

(INCH)

UNIT:

OUTLET SIDE

INLET SIDE

0.60

0.12

0.24

0.36

0.48

(I

N

H

O

)

A

ir

P

re

s

s

u

re

2

(m

m

H

O

)

Air Flow

18.0

0

2

0

0

0

3.0

.30

12.0

6.0

.15

.45

9.0

6.0

15.0

12.0

(CFM)

(M /MIN)

24.0

.60

.75

3

0.72

GFB0412XE

18.0

*

Bearing Type

*

Lead Wires :

*

Weight : 50g (1.766 OZ)

*

Material

Ball Bearings

UL 1061 AWG #24 OR Equivalent
Red Wire Positive(+)
Black Wire Negative(-)

Impeller & Frame : Plastic(UL 94V-0)

Operating

Voltage

Range

MODEL

Rated

Voltage

Maximum

Air Flow

Maximum

Air Pressure

Noise

PART NO. FUNCTION VDC VDC Amp Watt R.P.M. CFM mmH O IN H O dB-A

2

2

GFB0412SHE -R00 / -F00

12

7.0 to 13.2

0.56

6.72

10000/9600

0.630

22.25

15.09

0.594

57.5

* Function type is optional.
* The max. air flow and the speed are measured in free air ; max. air pressure is measured at zero air flow.
* Noise is measured in anechoic chamber in free air, one meter from intake side.
* All readings are typical values at rated voltage.
* Specifications are subject to change without notice.

Speed

(Front /Rear)

74

http://www.deltaww.com

Input

Power

Input

Current

Advertising