Dometic RM 6270(L) User Manual
Page 27

27
3. Wiring diagram with automatic ignition and no interior light
4. Wiring diagram with automatic ignition and interior light
spark plug
light DC --
reed contacts
(sensor switching)
* resistor (replaced by a bridge for 24V battery voltage)
ignition
control
lamp
thermo cut-off current
mains connection
~
to casing
heating-
element
AC
~
ground
battery connection
12V/24V --
mains connection
~
to casing
thermo cut-off current
heating-elem
ent
DC
-
reigniter
spark plug
to casing
to casing
heating-
element
AC
~
from battery
heating-element
DC
-
Battery connection 12V/24V -
A = Ground heating element DC, white
B = Heating element DC-,
red
C = Ground automatic ignition, black
D = Automatic ignition
violet
ground
ignition
control
lamp
to casing
battery connection
12V/24V --
* resistor
to casing
Battery connection 12V/24V -
A = Ground heating element DC, white
B = Heating element DC-,
red
C = Ground, automatic ignition black
and interior light,
D = Automatic ignition and violet
interior light
from