FIREPLACE INSTALLATION

Continued

FIREPLACE INSTALLATION

Checking Gas Connections (Cont.)
Removing/Replacing Glass Door

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.

Close equipment shutoff valve (see Figure 33).

2.

Pressurize supply piping system by either opening propane/LP
supply tank valve for propane/LP gas fireplace or opening main
gas valve located on or near gas meter for natural gas fire-
place, or using compressed air.

3.

Check all joints from propane/LP supply tank or gas meter to equip-
ment shutoff valve (see Figure 34 for propane/LP or Figure 35 for
natural gas). Apply noncorrosive leak detection fluid to all joints.
Bubbles forming show a leak. Correct all leaks at once.

Pressure Testing Fireplace Gas Connections

1.

Open equipment shutoff valve (see Figure 33).

2.

Open propane/LP supply tank valve for propane/LP fireplace
or main gas valve located on or near gas meter for natural
gas fireplace.

3.

Make sure control knob of fireplace is in the OFF position.

4.

Check all joints from equipment shutoff valve to gas valve
(see Figure 34 for propane/LP or Figure 35 for natural gas).
Apply noncorrosive leak detection fluid to all joints. Bubbles
forming show a leak. Correct all leaks at once.

5.

Light fireplace (see Operating Fireplace, pages 24 and 25).
Check all other internal joints for leaks.

6.

Turn off fireplace (see To Turn Off Gas to Appliance, page 24).

REMOVING/REPLACING GLASS DOOR

CAUTION: Do not operate this fireplace with a

broken glass door panel or without the glass door
panel securely in place. For replacement part infor-
mation see

Replacement Parts, page 29.

Removing Louver Panels

Remove the top and bottom louver panels by simultaneously pulling
both top end spring latches towards the center of the appliance until
they are disengaged from the locating holes (see Figure 36). Repeat
for bottom spring latches and pull the louvers outward. To install or
replace items removed, simply reverse the procedures above.

Figure 36 - Removing Louver Panel

Louver Panel

CAUTION: Wear gloves and safety glasses while

handling or removing broken glass. Do not remove if
glass is hot. Keep children and pets away from glass.

WARNING: If fireplace has been running, turn

off and unplug fireplace. Let cool before removing
glass door or louvers.

Spring Latch

Figure 34 - Checking Gas Joints for Propane/LP Gas Fireplace

Propane/LP
Supply Tank

Gas Valve

Equipment Shutoff Valve

Figure 35 - Checking Gas Joints for Natural Gas Fireplace

Gas
Meter

Gas Valve

Equipment Shutoff Valve

Open

Closed

Equipment
Shutoff
Valve

Figure 33 - Equipment Shutoff Valve

Advertising