Service hints, Technical service, Service publications – Desa CBN20T EN User Manual

Page 22: Replacement parts, Troubleshooting

Advertising
background image

www.desatech.com

107882-01K

22

TROUBLESHOOTING

Continued

POSSIBLE CAUSE

1. Gas leak. See Warning

statement on page 21

2. Control valve defective

1. Foreign matter between con-

trol valve and burner

2. Gas leak. See Warning

statement on page 21

1. Not enough combustion/ven-

tilation air

OBSERVED PROBLEM

Gas odor even when control knob

is in OFF position

Gas odor during combustion

Moisture/condensation noticed

on windows

REMEDY

1. Locate and correct all leaks

(see Checking Gas Connec-

tions, page 13)

2. Replace control valve

1. Take apart gas tubing and

remove foreign matter

2. Locate and correct all leaks

(see Checking Gas Connec-

tions, page 13)

1. Refer to Air for Combustion

and Ventilation requirements

(page 5)

REPLACEMENT PARTS

Note:

Use only original replacement parts. This

will protect your warranty coverage for parts

replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If

they canʼt supply original replacement part(s),

call DESA Heating Productsʼ Technical Service

Department at 1-866-672-6040.
When calling DESA Heating Products, have

ready
• your name
• your address
• model and serial numbers of your heater
• how heater was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date
Usually, we will ask you to return the part to the

factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they

canʼt supply original replacement part(s), either

contact your nearest Parts Central (see page 30)

or call DESA Heating Products at 1-866-672-6040

for referral information.
When calling DESA Heating Products, have

ready
• model number of your heater
• the replacement part number

SERVICE HINTS

When Gas Pressure Is Too Low
• pilot will not stay lit
• burner will have delayed ignition
• heater will not produce specified heat
• propane/LP gas supply may be low
You may feel your gas pressure is too low. If so, con-

tact your local natural or propane/LP gas supplier.

TECHNICAL SERVICE

You may have further questions about installation,

operation, or troubleshooting. If so, contact DESA

Heating Productsʼ Technical Service Department

at 1-866-672-6040. When calling please have your

model and serial numbers of your heater ready.
You can also visit DESA Heating Productsʼ techni-

cal service web site at

www.desatech.com

.

SERVICE PUBLICATIONS

You can purchase a service manual from the address

listed on the back page of this manual. Send a check

for $5.00 payable to DESA Heating Products.

Advertising
This manual is related to the following products: