6

EMS-121X User Manual

www.emacoustics.co.uk

personnel following safe working practice. Should you be in any doubt whatsoever, please contact

your local dealer who will be able to refer you to a suitable rigging company.


Cabling and Amplifier Selection

The EMS-121X is designed to be used with professional power amplifiers providing the following power outputs:

EMS-121X

800W/channel into eight ohms

It is good practice to use an amplifier equal to the program power rating of the loudspeaker – so as to retain

sufficient headroom and good dynamic range. Care should be taken during operation to avoid amplifier clipping –

as this can cause serious damage to your loudspeakers. If in doubt, please contact your dealer who will be happy

to assist you in correct amplifier choice and setup.

Cabling


The EMS-121X is supplied as standard with Neutrik SpeakON

TM

NL4 connectors, wired pin 1+/1-. It is

recommended that the resistance of your cable is less than one tenth of the nominal system impedance. Given

below are the recommended maximum cable lengths for different cross-sections and impedances.

Conductor Cross Sectional Area

Maximum Recommended Cable Length

4 ohms

8 ohms

16 ohms

1.0mm

2

11m

22m

44m

1.5mm

2

17m

34m

68m

2.0mm

2

22m

44m

88m

2.5mm

2

29m

58m

116m

4.0mm

2

44m

88m

176m

6.0mm

2

66m

132m

264m

Pins 2+/2- on the SpeakON

TM

connectors are wired together to allow link-through with 4-core cables.


A small power amplifier working too hard is more likely to damage a loudspeaker than a large power amplifier

working within its operating range!