Service call check, Specifications – Dacor DCM24 User Manual

Page 28

Advertising
background image

26

A35411,DCM24S/B/R

SERVICE CALL CHECK

Please check the following before calling for service:

1. Place one cup of water in a glass measuring cup in the oven and close the door securely.

Operate the oven for two minutes at HIGH 100%.

A. Does the oven light come on?

YES _______

NO _______

B. Does the cooling fan work?

YES _______

NO _______

(Put your hand over the rear ventilating openings.)

C. Does the turntable rotate?

YES _______

NO _______

It is normal for the turntable to turn in either direction.

D. Is the water in the oven hot?

YES _______

NO _______

2. Remove water from the oven and operate the oven for 5 minutes at CONV 450°F.

A. Do CONV and COOK indicators light?

YES _______

NO _______

B. After the oven shuts off, is inside of the oven hot?

YES _______

NO _______

If “NO” is the answer to any of the above questions, please check electrical outlet, fuse and/or circuit
breaker.
If both are functioning properly, CONTACT YOUR NEAREST AUTHORIZED DACOR SERVICER. A
microwave oven should never be serviced by a “do-it-yourself” repair person.

NOTE: If time appearing in the display is counting down very rapidly, check Demonstration Mode on page 24

and cancel.

SPECIFICATIONS

AC Line Voltage:

Single phase 120V, 60Hz, AC only

AC Power Required:

1.55 kW 13.0A (Microwave)
1.55 kW 13.0A (Convection)

Output Power:

Microwave

900W

*

(IEC Test Procedure)

Convection Heater

1450W

Frequency:

2450 MHz

Outside Dimensions:

24

5

/

8

”(W) x 14

7

/

8

”(H) x 19”(D)

Cavity Dimensions:

16

1

/

8

”(W) x 9

5

/

8

”(H) x 16

1

/

8

”(D)

Oven Capacity:

1.5 cft

Cooking Uniformity:

Turntable system

Weight:

Approx. 60 lbs.

*

the International Electrotechnical Commission’s standardized method for measuring output wattage. This
test method is widely recognized.

In compliance with standards set by:

FCC

–

Federal Communications Commission Authorized.

DHHS

–

Complies with Department of Health and Human Services (DHHS) rule, CFR, Title 21, Chapter I,
Subchapter J.

–

This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc.

Advertising