Installation requirements (cont.) – Fire Magic Diamond Single Sideburner 32794-1 Series User Manual

Page 10

Advertising
background image

10

The control panel MUST remain removable for servicing
(see PARTS LIST).

THIS UNIT MUST NOT BE LOCATED IN A FULLY
ENCLOSED AREA OF ANY KIND.

ENSURE PROPER COMBUSTION AIR AND
COOLING AIRFLOW

Proper airfl ow (Fig. 10-1) MUST be maintained for the
sideburner to perform as it was designed. If airfl ow is
blocked, overheating and poor combustion will result.
Do not block the 1" front air inlet along the bottom of
the control panel or more than 75% of the cooking grid
surface with pans or griddles.

GAS-SUPPLY PLUMBING REQUIREMENTS

For natural gas or a household propane system, rigid

1

/

2

" or

3

/

4

" black steel pipe or local code-approved

pipe is required to conduct the gas supply to the unit.
Contact your local gas supplier. Connect this pipe to a
required C.S.A.-approved stainless-steel fl ex connector

(attached). An NPT adapter has been provided for

1

/

2

"

pipe. DO NOT use a rubber hose within the unit
enclosure.
Apply only joint compounds that are resistant
to all gasses to all male pipe fi ttings except fl are fi ttings.
Make sure to tighten every joint securely.

Note: If

1

/

2

" pipe is used with natural gas, it should

be no longer than 20'.

Important: An external valve (with a removable

key) in the gas line is necessary for
safety when the unit is not in use. It also
provides for convenient maintenance.

GAS SUPPLY AND MANIFOLD PRESSURES:

For natural gas - normal 7" (17.78 cm) water column
(w.c.), minimum 5" (12.7 cm), maximum 10

1

/

2

" (26.7

cm). For propane gas - normal 11" w.c., minimum 10"
(25.4 cm), maximum 13" (33 cm).

INSTALLATION REQUIREMENTS (cont.)

REV 2 - 1502100745

L-C2-378

Fig. 10-1 Ventilation Diagram

DO NOT BLOCK

MORE THAN 75% OF

COOKING AREA

Advertising