Flowserve DMX User Manual

Page 9

Advertising
background image

DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 85392728 - 10/09

Page 9 of 60



Brake Horse Power at Best Efficiency
Point.

dBA

3 to 14 Stages

90 to 110

79

110 to 140

80

140 to 180

81

180 to 220

82

220 to 280

83

280 to 360

84

360 to 450

85

450 to 560

86

560 to 720

87

720 to 900

88

900 to 1125

89

1125 to 1400

90

1400 to 1800

91

1800 to 2250

92

2250 to 2800

93

2800 to 3600

94

3600 to 4500

95

4500 to 5700

96

5700 to 7200

97

7200 to 9000

98

9000 to 11,000

99

11,000 to 14,000

100


1.9.3

Combined noise levels for pump and
driver components

When two or more sources produce noises that are
sufficiently unrelated (so that interference effects do
not occur) the total combined noise level may be
obtained by a simple addition of dB values according
to the below table.

Difference between two
levels to be Combined, dB

Add to higher level to
obtain Combined level, dB

0

3

1

2.5

2

2

4

1.5

6

1

9

0.5

10

0

Advertising