6.11.7 Coupling, motor and ancillaries
a) Reconnect pump ancillary fittings and piping.
b) Install pump into sump and connect up remaining

fittings and piping.

c) Re-check freedom of shaft to rotate by hand.
d) If pump has an oil lubricated thrust bearing, ensure

the oil breather and oiler are assembled in their
correct tappings as shown below and fill with the
correct grade and quantity of oil through the oiler.

e) Re-install motor (check for correct rotation) and

then fit coupling drive element and guards.

f)

If all is correct continue with the procedure described
under Section 4, Installation and section 5,
Commissioning, start-up, operation and shutdown.