Installation, Operation – Desa 375-F User Manual

Page 5

Advertising
background image

www.desatech.com

116699-01B

5

INSTALLATION

WARNING: Review and un-

derstand the warnings in the

Safety Information section, page

2. They are needed to safely op-

erate this heater. Follow all local

codes when using this heater.

WARNING: Test all gas piping

and connections for leaks after

installing or servicing. Never use

an open flame to check for a leak.

Apply a mixture of liquid soap

and water to all joints. Bubbles

forming show a leak. Correct all

leaks at once.

1. Provide propane/LP supply system (see Pro-

pane/LP Supply, page 4).

2. Connect POL fitting on hose/regulator assem-

bly to propane/LP tank(s). Turn POL fitting

counterclockwise into threads on tank. Tighten

firmly using a wrench. IMPORTANT: Tighten

regulator with black adjustment knob point-

ing down. Pointing adjustment knob down

protects regulator from weather damage.

3. Connect hose to inlet connector. Tighten firmly

using a wrench.

IMPORTANT:

Extra hose or piping may

be used if needed. Install extra hose or pip-

ing between hose/regulator assembly and

propane/LP tank. You must use the regulator

supplied with the heater.

4. Open propane/LP supply valve on propane/LP

tank(s) slowly. Note: If not opened slowly, ex-

cess-flow check valve on propane/LP tank will

stop gas flow. If this happens, you may hear a

click inside the regulator assembly. To reset

the excess flow check valve, close propane/LP

supply valve and open again slowly.

OPERATION

WARNING: Review and un-

derstand the warnings in the

Safety Information section, page

2. They are needed to safely op-

erate this heater. Follow all local

codes when using this heater.

TO START HEATER

1. Follow all installation, ventilation and safety

information.

2. Locate heater on stable and level surface.

Make sure strong drafts do not blow into front

or rear of heater.

3. Plug power cord of heater into a three-prong,

grounded extension cord. Extension cord must

be at least six feet long. Extension cord must

be UL listed.

Extension Cord Size Requirement

Up to 50 feet (15 m) long, use 18 AWG

rated cord.

51 to 100 feet (15.5 to 30.5 m) long, use 16

AWG rated cord.

101 to 200 feet (30.78 to 61 m) long, use 14

AWG rated cord.

4. Plug extension cord into a 120 volt/60 hertz,

three-hole, grounded outlet.

Propane/LP
Tank

Supply
Valve

Hose

POL Fitting

Regulator

Adjustment Knob
(pointing down)

Figure 3 - Regulator With Adjustment

Knob Pointing Down

Figure 4 - Hose and Inlet Connector

Hose

Inlet Connector

5. Adjust regulator between 7 and 20 psig. Note:

Higher regulator setting will allow heater to

produce more heat.

6. Check all connections for leaks.
7. Close propane/LP supply valve.

WARNING: Do not adjust

regulator below 7 psig or above

20 psig. Heater may not run

properly.