Service publications, Specifications, Accessories – Desa 375-F User Manual

Page 8: Technical service, Service procedures

Advertising
background image

www.desatech.com

116699-01B

8

SPECIFICATIONS

• Output Rating - 225,000 to 375,000 (Btu/Hr)
• Fuel - Propane/LP Vapor Only
• Fuel Consumption

Gallons(liters)/Hour - 2.5 (9,4) Min/4.0 (15) Max

Pounds(kg)/Hour - 10.4 (4.7) Min/17.4 (7.9) Max
• Supply Pressure To Regulator

Minimum* - 25 psig (172 kPa)

Maximum - Tank Pressure
• Regulator Outlet Pressure -

7-20 psig (48 to 138 kPa)
• Hot Air Output - 1500 CFM (pi³/min)
• Motor - 1725 RPM, 1/5 HP
• Electric Input - 120 V/60 Hz
• Amperage - 4.2
• Ignition - Electronic Direct Spark, D.S.I.
* (for purposes of input adjustment)

ACCESSORIES

Purchase accessories and parts from your nearest

dealer or service center. If your dealer or service

center can not supply an accessory or part, either

contact your nearest Parts Central (listed in the

separate Authorized Service Center booklet) or

call DESA Heating Products at 1-866-672-6040

for referral information. You can also write to the

address listed on the back page of this manual.
Fuel Gas Connector: LPA4020
A POL adapter with excess-flow check valve.
Thermostat: HA1210

TECHNICAL SERVICE

You may have further questions about installation,

operation or troubleshooting. If so, contact DESA

Heating Productsʼ Technical Service Department

at 1-866-672-6040. When calling please have your

model and serial numbers of your heater ready.
You can also visit DESA Heating Productsʼ techni-

cal services web site at

www.desatech.com

.

15. Replace fan on motor shaft. Make sure set-

screw is touching back of flat surface on motor

shaft (see Figure 9).

16. Place setscrew on flat of shaft. Tighten set-

screw firmly (40-50 inch-pounds).

17. Remove two nuts and bolts securing motor

mount to shell.

18. Pull motor and fan from shell. Turn motor

and fan around. Carefully place back in shell.

Note:

Fan will go into shell first.

19. Line up mounting holes in shell with holes on

motor mount. Replace four bolts through shell

and motor mount. Insert bolts from outside of

heater. Tighten nuts firmly.

20. Route motor wires through hole in bottom of

shell (see Figure 6, page 7).

21. Connect motor wires as follows (see Figure

5, page 7):
• white wire—to terminal board

Note: Attach to empty connector on white

wire side of terminal board

• black wire—to terminal board

Note: Attach to empty connector on black

wire side of terminal board

• blue wire—to thermal switch wire

• orange wire—to solenoid valve

• green wire—to grounding screw on shell

22. Replace side cover.
23. Replace fan guard.

Fan

Hub

Setscrew

Motor
Shaft

Figure 9 - Fan Cross Section

SERVICE PROCEDURES

Continued

SERVICE PUBLICATIONS

You can receive an Illustrated Parts List free of

charge. Send your request and a self-addressed,

stamped envelope to DESA Heating Products

(address on back page). Be sure to include the

heater model number. You can purchase a service

manual for $5. Make check payable to DESA

Heating Products.