2.5 Lubricate the other stationary face seat gasket O-ring with

water or soap solution and place this O-ring on the back shoulder

of the remaining stationary face. Slide the inner stationary face

with the O-ring into position at the bottom of the chamber.

2.6 Wipe the seal faces clean with alcohol. Seal faces should not be

lubricated but should be left clean and dry.

Caution: Consult material safety data sheets for proper handling

of alcohol.

2.7 Install the seal chamber (pump back-plate) and assemble

the pump. Position the gland to the face of the seal housing.

Be sure the gland pilot is properly engaged. Tighten the gland

stud nuts evenly, cross stagger the adjustment of the nuts.

Follow the equipment manufacturer’s recommendation for gland

stud nut torque. In the absence of recommendations, gland stud

nuts should only be torqued to establish a leak tight seal at the

gland gasket. Proper land bolt adjustment is especially important

with clamp style inserts where torque may damage the insert.

In this case, gland stud nuts should be torqued to a maximum

of 13.5 N-m (10 ft-lbs).

2.8 See section 4, Operational Recommendations, before starting

pump.

3 Double Suction and Multistage Horizontal Split Case

Pumps (2 seal chambers)

4

Note: The parting gasket between the upper and lower sections of

the pump casing must be flush with the seal chamber bore and face

or leakage will occur past the O-rings and gaskets.
3.1 Lubricate the shaft or sleeve and the seal chamber bore with

water or a mild water soluble soap solution.

3.2 Lubricate one stationary face seat gasket O-ring with water

or soap solution and place this O-ring on the back shoulder of the

inner stationary face. Slide the stationary face with the O-ring into

position at the bottom of the chamber. Do not bump the stationary

face against the shaft as it may chip, crack, or break.