5 operational recommendations, 6 repair – Flowserve Single Inside Pusher Type Seal User Manual

Page 7

Advertising
background image

Proper gland bolt adjustment is especially important with clamp

style stationary faces where excessive torque may damage the

face.

4.11 Assemble the pump.

4.12 See Operational Recommendations before starting pump.

5 Operational Recommendations

5.1 Do not start up the equipment dry. Vent air from the casing of the

pump and the seal chamber before startup. Circulate clean product

or a clean fluid from an external source through the seal chamber

whenever the equipment is in operation, API Plan 11 or 32.

5.2 If the seal runs hot, check for proper seal setting, seal housing

dimensions, and check the bypass or flush line for obstructions.

Do not allow the equipment to run for any extended time if the

seal gets hot or squeals.

For special problems encountered during installation, contact your

nearest Flowserve Sales and Service Representative or Authorized

Distributor.

6 Repair

This product is a precision sealing device. The design and dimension

tolerances are critical to seal performance. Only parts supplied by

Flowserve should be used to repair a seal. To order replacement parts,

refer to the part code and B/M number. A spare backup seal should be

stocked to reduce repair time.
When seals are returned to Flowserve for repair, decontaminate the

seal assembly and include an order marked "Repair or Replace."

A signed certificate of decontamination must be attached.
A Material Safety Data Sheet (MSDS) must be enclosed for any

product that came in contact with the seal. The seal assembly will be

inspected and, if repairable, it will be rebuilt, tested, and returned.

7

torque. In the absence of recommendations, gland nuts should

only be torqued to establish a leak tight seal at the gland gasket.