6 piping instructions – Flowserve X Series BW Seals User Manual
Page 7

7
Type 2 (setting plates)
Figure 5
• Tighten drive collar set screws to shaft.
• Loosen setting plate attachment bolts and rotate setting plates clear of drive collar.
• Retighten setting plate attachment bolts with setting plates clear of drive collar.
Setting Plate Bolt
Setting Plate
Set Screw
Type 3 (setting blocks)
Figure 6
• Tighten drive collar set screws to shaft.
• Loosen and remove setting blocks.
6 Piping Instructions
Do not start up the equipment dry. Vent air from the casing of the pump and the seal
chamber before start-up.
Refer to seal assembly drawing for mechanical seal piping instructions.
Note:
For special problems encountered during installation, contact your nearest
Flowserve Sales and Service Representative or Authorized Distributor.
Setting Block