4.3 Install the stationary face assembly and the seal carrier on to the
pump. See Figure 6.
4.3.1 Apply silicon grease to the outside diameter of the seal
carrier 240 .
4.3.2 Slide the assembly into the seal cavity until 71 O-ring is
located near the end of the seal carrier next to the
stationary seal assembly 14 .
4.3.3 Attach 101 clamp ring to 240 seal carrier with 40-1 bolts.
Assemble the Stationary Face Assembly
Figure 5
Silicon Grease
Stationary Face Assembly 14
Seal Carrier
240
Assemble the Stationary Face Assembly
Figure 6
Seal Carrier
240
Bolt
40
Clamp Ring
101
Stud 10
Bolt
40-1
Jam Nut
9
End Plate 139
O-ring
71
Seal Face
Cover
46
Stationary
Seal Assembly
14