4 Operational Recommendations

4.1 Do not exceed corrosion limits. The 86/87 seal is designed to

resist corrosion by most chemicals. However, do not expose the

86/87 materials of construction to products outside of their cor-

rosion limits. Consult Flowserve, Flow Solutions for assistance.

4.2 Do not exceed the Pressure limits of the 86/87 seal, consult

Flowserve, Flow Solutions for assistance.

4.3 Do not exceed the temperature limits of the 86/87 seal. The

materials of construction are listed on the box label. Turn on

cooling water to the supply tank before start-up if the tank has

coils.

4.4 Do not start up or run the 86/87 seal dry. Buffer/barrier fluid must

be in the seal cavity at all times during pump operation.

For special problems encountered during installation, contact your nearest

Flowserve Sales and Service Representative or Authorized Distributor.