3dispensing variations, Time delay to dispense figure 3 – Flowserve SLD User Manual

Page 6

Advertising
background image

6

2.3 If it is desired to decrease or increase the rate of lubricant dispensing after

initial setting, simply click all the DIP switches to “Off” and reselect the new

dispensing period desired.

2.4 To turn off the SLD auto-luber unit during periods of extended equipment

shutdown (months), click all the DIP switches, including the “Blip” light,

to “Off”. Reactivate settings prior to placing equipment back into normal

operation. See paragraph 4 Maintenance for blip light indicators.

3

Dispensing Variations

Variables can be considered when selecting the dispensing rate based on the

operating environment. The SLD auto-luber dispensing rates are based on seal

quench chamber parameters found at normal sea level atmospheric conditions

of 101 kPa and 20°C (14.7 psia and 68°F) and for equipment shaft diameters of

100 mm (4 inch). In general, it is a good practice to first select a faster dispensing

rate than anticipated and make adjustments based on actual field observations.

Because of the wide number of variables found with each application, the

following information is being provided only as a guide for making an informed

decision when selecting the appropriate dispensing rate. There is an additive

effect of variables that can cancel or compound with each other. This may help

explain why grease consumption varies between installations, seasons, or from

published rates.

3.1 Altitude Effect

The rate of dispensing will increase at higher altitudes and decrease at lower

altitudes because of the difference in atmospheric pressure acting against

the SLD auto-luber unit. For every change in elevation of 305 meters (1000

feet) from sea level, the discharge rate will naturally increase or decrease

by an additional 5%. For example, at 610 meters (2000 feet) above sea

level, the dispensing rate will be 10% faster. Similarly, at 305 meters (1000

feet) below seal level, the dispensing rate will be 5% slower. Installation

at high altitude may require selection of a slower dispensing rate to help

compensate.

3.2 Temperature Effect

The rate of dispensing will increase at higher temperatures and decrease

at lower temperatures because of the change in lubricant viscosity.

For every change in temperature of 5.5°C (10°F) above or below ambient,

the discharge rate will naturally increase or decrease by an additional 4%.

Time Delay to Dispense

Figure 3

Time Delay to Dispense

Month Switch

1 mo. 2 mo. 3 mo. 6 mo. 12 mo. B

Days Delay

1

2

3

5

10

20

to Start

Advertising