Operational recommendations – Flowserve SL-5000 Seals User Manual

Page 4

Advertising
background image

4

Operational Recommendations

3 SL-5000
3.1 Do not start the equipment dry. Never start up the equipment

without properly venting the pump of air.

3.2 If the seal runs hot, check for proper seal setting, seal housing

dimensions, and check the flush lines for obstructions. Do not

allow the equipment to run for any extended time if the seal gets

hot or squeals.

4 SL-5200
Figure 2 contains guidelines for buffer fluid systems which can be

used with the SL-5200 double seal. Figure 3 is a suggested piping

arrangement for the SL-5200 with circulating feature and supply tank

with cooling coil. For other sealing liquid systems using Dura Circulators,

external flushing or thermal convection, refer to the assembly drawing or

consult Flowserve, Flow Solutions for instructions.
4.1 Always start up the sealing liquid supply before starting

equipment. Be sure that the sealing liquid pressure is greater

than the maximum pressure of the process fluid acting on the

seal chamber.

4.2 Seal liquid pressure must not exceed the pressure velocity rating

of the seal design and materials of construction.

4.3 Be sure cooling water to supply tank or circulator is on.
4.4 Never start up equipment dry. Properly vent all air.
4.5 If the seal runs hot or squeals, check the seal liquid flow between

the seals and check the seal housing dimensions to insure that the

seal is not over-compressed.

For special problems encountered during installation, contact your

nearest Flowserve Sales and Service Representative or Authorized

Distributor.