(cont.)

5. To avoid damage to the O-Ring, carefully screw the

By-Pass Valve into the Body until the O-Ring engages

the Body. Screw the valve in ½ turn, and unscrew ¼

turn. Repeat this procedure until the O-Ring has

entered the Body and the By-Pass Valve has seated.

CAUTION: If hydraulic fluid is present in

the By-Pass Valve cavity of the Body, fluid

back pressure may shear the O-Ring and the

O-Ring will have to be replaced.

6. After installing a new By-Pass Valve, recharge the

gun with hydraulic fluid as described in this brochure.

Floating Piston Replacement

1. Remove the Sealant Barrel Cap (26) and open the

By-Pass Valve (12).

2. Push Piston Assembly to bottom of Sealant Barrel (24)

with Handle (1). Clean the Handle and replace.

3. Remove the Sealant Barrel from the gun (see

instructions listed in Sealant Barrel Replacement).

4. Remove the Floating Piston (41) from the Sealant

Barrel using Piston Pulling Tool 47517.

5. Place the Floating Piston into a vise and disassemble

using Spanner Wrench 47518.

6. Replace the O-Ring (42) and Nylon Cups (35).

7. Tighten the assembly using two spanner wrenches.

8. Replace the Floating Piston using Floating Piston Guide

Tool 47520. The assembly should be positioned flush

with the bottom of the Sealant Barrel.

9. After installing the Floating Piston, recharge the

gun with hydraulic fluid as described on page 8 of

this brochure.

Sealant Change-out

1. Remove the Sealant Barrel Cap (26), complete with

hose assembly.

2. Force Piston Pulling Tool 47517 into the center of

the sealant in the Sealant Barrel (24) and push until

the tool is in contact with the Floating Piston (41).

3. Screw the tool into the Floating Piston, open the

By-Pass Valve (12), and pull the piston out of the barrel

until the assembly is flush with the end of the barrel.

4. Remove the Piston Pulling Tool and scrape the

existing sealant from the end of the Floating Piston.

5. Follow instructions for Loading the 400-D Hand Gun

with Sealant as listed in this brochure.

6. Attach a sealant fitting to the Giant Button Head

Coupler (44) and purge old sealant from the hose by

operating the gun until new sealant is pumped through

the fitting.