ValveAnalysis Diagnostic Software Module FCD VLENIM0113-01 – 1/06

10

Balance Pressure

The balance pressure is (P1+P2)/2 for a double-acting actuator. Shifts in the balance pressure
indicate an air leak in the actuator.

Valve/Actuator Friction

Plots the overall friction of the device. This is an excellent plot to use in determining the health
of the valve.