4.0 TEST CONDITIONS
4.1
Each valve covered by this manual has received the following hydrostatic tests with no measurable leakage
4.1.1
A shell hydrostatic test at 1.5 times the 100°F pressure rating.
4.1.2
A seat leakage and disc closure test at 110% of the 100°F pressure rating.
4.1.3
A backseat leakage test at 110% of the 100°F pressure rating.
4.1.4
A packing test at 110% of the 100°F pressure rating.
1888-lb. Double-Disc Gate Valve FCD ADENIM0001-00