Replacing stuffing box, valve seat and valve plug PA 46, PA 47

. Undo retaining piece for forkhead

T and pull out hand lever 1. Fig. 3

. Unscrew hexagonhead cap screws

W and remove locking lever A.

3. Remove pressure plate

V and mounting bracket B.

4. Pull out split pin

S.

5. Use openend spanner A. F. 8 mm to unscrew the pressure pin

R from the valve plug D.

6. Remove compression spring

P.

7. Use openend spanner A. F. 3 mm to unscrew the union nut

O.

8. Unscrew sealing plug

G and remove gasket F.

9. Pull out valve plug

D.

0. Take out internal parts

N M L K L J of stuffing box.

. Use steel punch to knock the valve seat

H out of the valve body I. Fig. 7

. Clean stuffing box and valve body.
3. Insert new valve seat

H such that two opposite holes are in the flow direction of the intermittent

valve.

4. Use punch made of CuZn to fix the valve seat in the valve body.

Fig. 8

5. Reinsert valve plug

D and use abrasive paste type TETRABOR

®

F400 for polish grinding.

6. Insert new gasket

F and screw in sealing plug G. Tighten with a torque of 350 Nm.

7. Reinsert internal parts of stuffing box according to order as specified on page 4.

Fig. 5, Fig. 6

8. Apply heatresistance lubricant to stuffing box thread (use e.g. WINIX

®

50).

9. Align valve plug

D such that the hole for the split pin S is perpendicular to the flow direction of the

intermittent valve.

0. Use openend spanner A. F. 3 mm to screw in union nut

O and tighten at room temperature with

a torque of

55 Nm.

. Apply heatresistant lubricant to both sides of the compression spring

P (use e. g. WINIX

®

50)

and place it onto the union nut

O.

. Use openend spanner A. F. 8 mm to screw the pressure pin

R onto the valve plug D until the

holes for the split pin

S in the valve plug and the pressure pin overlap.

3. Insert split pin

S.

4. Put mounting bracket

B and pressure plate V in place. Align check hole C to the right.

5. Insert and screw in hexagonhead cap screws

W and locking lever A and tighten them in

diagonally opposite pairs, applying a torque of

20 Nm.

6. Insert hand lever

1 and fix it to the forkhead T by means of retaining piece 3.

7. Operate valve once (open it until it hits the stop).

WINIX

®

50 is a registered trademark of WINIX GmbH, Norderstedt

TETRABOR

®